6 research outputs found

    Calculation methods of high temperature distribution within structural components and application of these methods to fire resistance assessment

    Get PDF
    Fire resistance of a building structure is one of important properties which describes the behaviour of the structure exposed to fire. Performance based on codes allows to use calculation methods. Given a satisfactory characterisation of the heat exposure, the designer may then compute how quickly temperatures will increase at various sections within the structural component. There are many calculation methods. They can divided into three groups (Fig 1): using experimental data, using both temperature conduction process and non-stationary thermal conduction. Thermal conduction, temperature conduction and thermal capacitance are general properties for temperature prediction methods. Usually building materials have thermal characteristics for normal environment, which can not exactly describe material properties at high temperatures. But many calculation methods lack accurate thermal characteristics describing building material properties at high temperatures. This article is intended for the analysis of this question. First Published Online: 30 Jul 201

    Design of people evacuation from rooms and buildings

    Get PDF
    There is a fire hazard in many civil buildings or engineering structures. Analysis of people evacuation time from the room or building is an important part of the designing process. Nevertheless, analysis of human behaviour in fire conditions is very complicated. Various factors should be evaluated, physical and even psychical, influencing safe evacuation of people from buildings. The analytical and calculating methods created are intended for analysis of people evacuation in fire conditions. Unfortunately, use of complicated calculations for determination of people evacuation requires too many resources; therefore, their application is limited. The calculation method for people evacuation presented in this paper is based on dependencies of the physical characteristics of people stream (density, intensity, movement speed) on people movement manner. The time required to evacuate people from people gathering room and building is determined in the numerical illustration of the method application. The article presents the comparison of simple calculation method and modeling with FDS+Evac software results of time for safe evacuation of people from rooms and buildings. Santrauka Daugelyje civiliniu pastatu ar inžineriniu statiniu kyla gaisro rizikos pavojus. Žmoniu evakuacijos laiko iš patalpos ar statinio analize yra svarbi projektavimo dalis. Tačiau žmoniu elgsenos gaisro salygomis analize yra labai sudetinga. Ivairūs fizikiniai ir netgi psichologiniai veiksniai, darantys itaka saugiai žmoniu evakuacijai iš statiniu, turi būti ivertinti. Išrasti analitiniai ir skaičiuojamieji metodai, skirti žmoniu evakuacijai gaisro salygomis analizuoti. Deja, sudetingu skaičiavimu metodu taikymas žmoniu evakuacijai nustatyti reikalauja pernelyg daug ištekliu, todel ju taikymas yra ribotas. Šiame straipsnyje pateikiamas žmoniu evakuacijos skaičiavimo metodas, paremtas fizikinemis žmoniu srauto charakteristikomis (tankiu, intensyvumu, judejimo greičiu), priklausomai nuo žmoniu judejimo būdo. Palyginti aprašyto ir sudetingojo žmoniu evakuacijos skaičiavimo metodu, naudojant FDS+Evac programine iranga, rezultatai. Published Published Online: 24 Jun 2011 Reikšminiai žodžiai: žmoniu evakuacija, sauga, evakuacijos laikas, FDS+Eva

    Research on low power Savonius rotor wind power plant

    No full text
    https://doi.org/10.15544/2669-1728.2021.26Pasirinkta Savonijaus tipo 60 W galios vertikali vėjo jėgainė (trijų menčių). Tyrimo tikslas yra ištirti vertikalios ašies vėjo jėgainę ir nustatyti transporto sukeltų vėjo gūsių įtaką vėjaračio apsukoms. Pasirinkta tyrimo vieta – tarptautinis greitkelis „Via Baltica“. Kelio ruože už Akademijos miestelio pastatytas tyrimo stendas. Jėgainės rodikliai matuoti esant 0 m, 0,5 m, 1 m, 1,5 m, ir 3 m atstumui nuo važiuojamosios dalies. Atlikus tyrimą ir skaičiavimus nustatyta, kad ši vėjo jėgainė įsisuka nuo pravažiuojančio sunkiasvorio transporto srauto, o vidutinis vėjo gūsio greitis tarp mažiausio atstumo 0 m šalia važiuojamosios dalies ir 3 m atstumo skiriasi 2 m/s. Vidutinės vėjo jėgainės rotoriaus apsukos svyruoja nuo 201±30 iki 355±35 apsisukimų per minutę, priklausomai nuo atstumo iki važiuojamosios kelio daliesSelected Savonius type 60 W power vertical wind turbine (three blades). The goal is to investigate a vertical axis wind turbine and determine the influence of wind turbine speed caused by wind gusts from the heavy transport. The chosen spot of this research – international highway “Via Baltica”. The research stand was located in one of road sections outside the Akademija town. The power plant performance was measured at 0 m, 0.5 m, 1 m, 1.5 m, and 3 m from the carriageway. According to the research and calculations, this wind turbine starts working from passing heavy transport traffic and there is 2 m/s average wind gust speed difference between the smallest distance 0 m near carriageway and 3 m distance. The average wind turbine rotor speed ranges from 201±30 to 355±35 revolutions per minute, depending on the distance to the carriagewayVytauto Didžiojo universitetasŽemės ūkio akademij

    Žmonių evakuacijos iš patalpų ir pastatų projektavimas

    No full text
    There is a fire hazard in many civil buildings or engineering structures. Analysis of people evacuation time from the room or building is an important part of the designing process. Nevertheless, analysis of human behaviour in fire conditions is very complicated. Various factors should be evaluated, physical and even psychical, influencing safe evacuation of people from buildings. The analytical and calculating methods created are intended for analysis of people evacuation in fire conditions. Unfortunately, use of complicated calculations for determination of people evacuation requires too many resources; therefore, their application is limited. The calculation method for people evacuation presented in this paper is based on dependencies of the physical characteristics of people stream (density, intensity, movement speed) on people movement manner. The time required to evacuate people from people gathering room and building is determined in the numerical illustration of the method application.The article presents the comparison of simple calculation method and modeling with FDS+Evac software results of time for safe evacuation of people from rooms and buildings.Lietuviška santrauka. Daugelyje civilinių pastatų ar inžinerinių statinių kyla gaisro rizikos pavojus. Žmonių evakuacijos laiko iš patalpos ar statinio analizė yra svarbi projektavimo dalis. Tačiau žmonių elgsenos gaisro sąlygomis analizė yra labai sudėtinga. Įvairūs fizikiniai ir netgi psichologiniai veiksniai, darantys įtaką saugiai žmonių evakuacijai iš statinių, turi būti įvertinti. Išrasti analitiniai ir skaičiuojamieji metodai, skirti žmonių evakuacijai gaisro sąlygomis analizuoti. Deja, sudėtingų skaičiavimų metodų taikymas žmonių evakuacijai nustatyti reikalauja pernelyg daug išteklių, todėl jų taikymas yra ribotas. Šiame straipsnyje pateikiamas žmonių evakuacijos skaičiavimo metodas, paremtas fizikinėmis žmonių srauto charakteristikomis (tankiu, intensyvumu, judėjimo greičiu), priklausomai nuo žmonių judėjimo būdo. Palyginti aprašyto ir sudėtingojo žmonių evakuacijos skaičiavimo metodų, naudojant FDS+Evac programinę įrangą, rezultatai

    Singularity and importance of determination of wood charring rate in fire investigation

    No full text
    In this paper experimental studies on charring of wood are reviewed with the objective of providing guidance for interpretation of char patterns in fire investigations. The present paper presents the available data on charring rates and char depth, causation of deep patterns and other. The paper similarly examines research data (on the grounds of ASTM E 119 and ISO 834), where exposure is controlled via the standard time-temperature curve, and data obtained from cone calorimeter or other bench-scale tests where the test conditions are set by specifying a heat flux, normally invariant over time, imposed on the specimen. 690 |a Charrin
    corecore